Whether your system needs routine maintenance or emergency repair, keeping a cooling tower running efficiently takes experience, precision, and the right parts on hand. MCS Cooling Tower Service provides comprehensive Cooling Tower Service in San Diego & Los Angeles, CA, and surrounding areas, helping facility managers and industrial operators avoid costly downtime and unnecessary repairs.

Call (909) 524-7098 today to have our team assess your system and find out what your cooling tower needs to run at peak performance.

Why Facility Managers Rely on Our Team

Cooling towers are complex systems with a lot of moving parts, and small issues left unaddressed tend to cascade into bigger, more expensive problems. Our technicians bring over 25 years of hands-on experience across nearly every cooling tower brand and configuration, which means we can accurately diagnose issues on the first visit rather than guessing our way through a repair. We’re comfortable working on occupied, operational job sites, and we understand that minimizing disruption to your facility is just as important as the repair itself.

What Our Cooling Tower Services Include

We offer a full range of services to keep your system running reliably, including:

  • Preventive maintenance and factory-spec inspections
  • Fan and fill kit installation to restore airflow and water flow
  • Motor change outs and mechanical repairs
  • Basin coating, leak sealing, and rust prevention
  • Refurbishments and complete rebuilds for aging systems

Regular service not only extends the lifespan of your cooling tower but also helps lower energy costs and prevent unplanned outages that can disrupt your operations.

If you already know what your system needs, we also offer focused services like Cooling Tower Fan Kits, Cooling Tower Motor Change Outs, and Cooling Tower Rust Prevention to address specific issues directly.

Schedule Your Cooling Tower Service Today

Don’t wait for a small issue to become a major breakdown. MCS Cooling Tower Service is ready to inspect, repair, and maintain your cooling tower with the same factory-spec standards we bring to every job.

Call (909) 524-7098 now to schedule your free system inspection and keep your cooling tower running efficiently all year long.

Most Recent Pins (5)

FERNANDO DE LA CRUZ
MCS Cooling Tower Service provides a twice-yearly cleaning program for five cooling towers in Bloomington, CA. The service includes power washing internal and external tower components, cleaning water basins and distribution systems, removing debris, and inspecting equipment to maintain efficiency and extend tower lifespan.
Check-in Location
Cooling tower exterior power washing by technician
FERNANDO DE LA CRUZ
MCS Cooling Tower Service refurbished the drive system of a Marley MHF7107 fluid cooler in a residential high-rise on Wilshire Boulevard, Los Angeles, CA. They replaced worn fan motor, sheaves, belts, bushings, and gear drives, reused fan assemblies, and ensured the system operated smoothly after service.
Check-in Location
Marley MHF7107 fluid cooler interior basin with water
Marley MHF7107 fluid cooler interior basin with waterMarley MHF7107 fluid cooler basin cleaning in high-riseMarley MHF7107 fluid cooler coil cleaning with pressure washerMarley MHF7107 fluid cooler fill media close-upMarley MHF7107 fluid cooler drive system refurbishment
FERNANDO DE LA CRUZ
MCS Cooling Tower Service rebuilt an aged BAC VC1-N275 evaporative condenser on a downtown Santa Ana building’s roof. The team replaced worn fans, drives, and drift eliminators during off-hours to minimize disruption. They ensured safety by locking out power, removed old parts, installed new components, and verified proper operation.
Check-in Location
Evaporative condenser drift eliminator mesh panel replacement
Evaporative condenser drift eliminator mesh panel replacementEvaporative condenser motor and belt drive systemBAC VC1-N275 evaporative condenser fan shaft and bearingsEvaporative condenser fan wheel and shaft assemblyEvaporative condenser fan motor and belt system
FERNANDO DE LA CRUZ
MCS Cooling Tower Service in Newport Beach, CA refurbishes Evapco LSCB 120 evaporative condensers by replacing worn fan and drive components and treating rust with a zinc-rich coating. They manage work in phases to maintain facility operations and restore condenser function efficiently.
Check-in Location
Evapco LSCB 120 evaporative condenser system maintenance
Evapco LSCB 120 evaporative condenser system maintenanceEvapco LSCB 120 condenser interior basin with waterEvapco LSCB 120 evaporative condenser fan assemblyEvapco LSCB 120 condenser fan and pulley assemblyEvapco LSCB 120 condenser basin with rust and corrosion
FERNANDO DE LA CRUZ
MCS Cooling Tower Service provides Evapco cooling tower preventative maintenance in Los Angeles, CA. They inspect, clean, and service cooling towers to ensure optimal performance and prevent breakdowns. This service helps maintain equipment efficiency and extends cooling tower life.
Check-in Location
Evapco cooling tower fan blade and casing inspection
Evapco cooling tower fan blade and casing inspectionCooling tower metal grid and frame with shadowsCooling tower water basin with float valve mechanismEvapco cooling tower basin with settling debrisEvapco cooling tower basin with maintenance access panel open