Cooling Tower Rebuilds in San Diego & Los Angeles, CA

Cooling Tower Rebuilds

Comprehensive Rebuilds That Extend Your Tower’s Lifespan

When a cooling tower has multiple aging or failing components, patchwork repairs often cost more in the long run than a full rebuild. MCS Cooling Tower Service provides thorough Cooling Tower Rebuilds in San Diego & Los Angeles, CA, and surrounding areas, restoring your system to like-new performance without the expense of a full tower replacement.

Call (909) 524-7098 today to have our team evaluate your tower and determine whether a rebuild can extend its service life significantly.

Why Facility Managers Choose a Rebuild Over Replacement

Replacing an entire cooling tower is a major capital expense, and in many cases, it isn’t necessary. Our technicians assess the structural integrity, mechanical components, and overall condition of your tower to determine which parts can be restored and which need to be replaced outright. With over 25 years of experience across every major brand and configuration, we’re able to rebuild towers to factory-spec performance at a fraction of the cost of starting over. This approach also minimizes downtime, since a rebuild can often be scheduled and completed far faster than a ground-up tower replacement.

What Our Rebuild Process Covers

Every rebuild is scoped to the specific condition of your tower, and typically includes:

  • Full structural and mechanical inspection to identify all points of wear
  • Replacement of fill media, fan components, motors, and belts as needed
  • Basin repair, coating, and leak sealing
  • Corrosion treatment and rust prevention application
  • Final walkthrough and reporting to confirm the tower meets performance standards

A properly executed rebuild can add years of reliable service to a tower that might otherwise be headed for costly replacement, all while helping you avoid the budget strain of a full system overhaul.

Since rebuilds often overlap with other services, we can incorporate Cooling Tower Basin Coating, Cooling Tower Rust Prevention, or Cooling Tower Motor Change Outs into the same project.

Schedule Your Rebuild Consultation Today

Don’t let an aging cooling tower become a bigger liability than it needs to be. MCS Cooling Tower Service is ready to inspect, rebuild, and restore your system with the same factory-spec standards we bring to every job.

Call (909) 524-7098 now to schedule your free rebuild consultation and find out how much life we can add to your existing system.

Most Recent Pins (4)

FERNANDO DE LA CRUZ
MCS Cooling Tower Service refurbished a two-cell Evapco SST 12-724 cooling tower in San Diego, CA. The project replaced fan and drive systems one cell at a time to maintain cooling without shutdown. The team removed old components, installed new parts, and ensured proper operation before completion.
Check-in Location
Cooling tower fan and drive pulley assembly close-up
Cooling tower fan and drive pulley assembly close-upEvapco SST 12-724 cooling tower fan and drive systemCooling tower fan shaft and pulley system inside cellCooling tower fan shaft and support assembly installationCooling tower fan drive system inside cell with pulley
FERNANDO DE LA CRUZ
MCS Cooling Tower Service refurbished the drive system of a Marley MHF7107 fluid cooler in a residential high-rise on Wilshire Boulevard, Los Angeles, CA. They replaced worn fan motor, sheaves, belts, bushings, and gear drives, reused fan assemblies, and ensured the system operated smoothly after service.
Check-in Location
Marley MHF7107 fluid cooler interior basin with water
Marley MHF7107 fluid cooler interior basin with waterMarley MHF7107 fluid cooler basin cleaning in high-riseMarley MHF7107 fluid cooler coil cleaning with pressure washerMarley MHF7107 fluid cooler fill media close-upMarley MHF7107 fluid cooler drive system refurbishment
FERNANDO DE LA CRUZ
MCS Cooling Tower Service rebuilt an aged BAC VC1-N275 evaporative condenser on a downtown Santa Ana building’s roof. The team replaced worn fans, drives, and drift eliminators during off-hours to minimize disruption. They ensured safety by locking out power, removed old parts, installed new components, and verified proper operation.
Check-in Location
Evaporative condenser drift eliminator mesh panel replacement
Evaporative condenser drift eliminator mesh panel replacementEvaporative condenser motor and belt drive systemBAC VC1-N275 evaporative condenser fan shaft and bearingsEvaporative condenser fan wheel and shaft assemblyEvaporative condenser fan motor and belt system
FERNANDO DE LA CRUZ
MCS Cooling Tower Service in Newport Beach, CA refurbishes Evapco LSCB 120 evaporative condensers by replacing worn fan and drive components and treating rust with a zinc-rich coating. They manage work in phases to maintain facility operations and restore condenser function efficiently.
Check-in Location
Evapco LSCB 120 evaporative condenser system maintenance
Evapco LSCB 120 evaporative condenser system maintenanceEvapco LSCB 120 condenser interior basin with waterEvapco LSCB 120 evaporative condenser fan assemblyEvapco LSCB 120 condenser fan and pulley assemblyEvapco LSCB 120 condenser basin with rust and corrosion
Check-ins - Reviews - Content - Ranking